โมดูลควบคุมการชาร์จแบตเตอรี่ 10A Battery Charger Controller Protection Board DC 6-60VThe battery charging control module automatically controls battery charging and discharging to protect the battery.
Specifications:
- Product Name: Digital control charging module
- Product Number: XY-L10A
- Control Voltage: DC 6V-60V
- Control Current: 10A(Max)
- Control Precision: 0.1V
- Output Type: Direct output
- Voltage Error: 0.1V
- Suitable for the battery: Storage Battery, Lithium battery
- Physical dimension: 79*42*18mm
Function Description:
1. Automatic Charge control function
By setting the Upper limit voltage volt-HI:‘UP’; Lower limit voltage volt-LI:‘dn’;
The relay turns ON and the charger starts charging for the battery when the current battery voltage is less than the lower limit voltage ‘dn’.
The relay turns OFF and completes an automatic charge when the Current battery voltage is more than the Upper limit voltage ‘UP’.
2. Charge Time Control Function
How to enable the time control function?
It will enable the time control function by setting the parameter ‘OP’ is not ‘0’ after entering the parameter set menu.
‘OP’ default parameter is:’--:--h’, the default does not turn on time control function;
After enable Time Control Function(‘OP’ is not equal to ‘0’):
Relay will turn ON and the charger starts charging the battery and the system starts timing when Current battery voltage is less than Lower limit voltage ‘dn’.
Relay will turn OFF and end charging if Current battery voltage is more than Upper limit voltage ‘UP’ during timing.
Relay will turn OFF and end charging if Current battery voltage is less than Upper limit voltage ‘UP’ but the time(‘OP’) has ended.
Relay will keep ON and charging if Current battery voltage is less than Lower limit voltage ‘dn’ even though the time(‘OP’) has ended.
Module will automatically turn off the charging time control function.And flashing ‘H:ER’ on screen to remind users that time parameter settings are unreasonable. Press any key to stop flashing.
Note: Time format: 00:59 (00 is hours, 59 is minutes) The maximum time is 99:59 which is about 100 hours.
3.UART communication and parameter settings
The system supports UART data upload and parameter setting functions (TTL level);
UART: 115200, 8, 1
NO. Command Function
1 ON Relays Enable
2 OFF Relays Disable
3 Start Start data upload
4 Stop Stop data upload
5 Read Read the parameter setting
6 dw10.0 Set volt-LI:'dn'
7 up20.0 Set volt-HI:'UP'
8 xx:xx Set the charge time 'OP'. 00:00 is used to stop charge time
Data upload message format:
Battery voltage + battery percentage + charging time + charging status
12.0V, 020%, 00:10, OP
Set Parameter:
1>.LCD will display 'SET' after enter set parameter menu by long press button 'SET'.
2>.Switch the set parameters by short pressing button ‘SET’.
3>.Set parameter value by long or short pressing button ‘UP’ and ‘DOWN’.
4>.Repeat step 2 and step 3 if need to set other parameters.
5>.Automatically save and exit the setup menu by long press button 'SET' after set all parameters.
Button Description:
Long press:keep press button for more than 3second.
In the normal display interface:
1>.Display the currently set parameters when short press button ‘SET’;
2>.Switch display charging percentage and charging time when short press button ‘UP’;
3>.Enable Relay ON or OFF when short press button ‘DOWN’.Relay will OFF and display OFF if disable relay.
4>.Set the status of the LCD backlight(L-P) when long press button ‘UP’.
OFF:The backlight will keep bright.
ON:Backlight will be automatically turned OFF after 5-10second.
5>.Long press ‘SET’ button to enter the parameter settings menu.
Calculation Voltage Percentage:
voltage percentage = battery voltage/(volt-HI – volt-LI)